Reset Service Reminder on Atlas Copco Compressor
A service reset on Atlas Copco compressor means clearing the controller reminder only after you finish the due service, such as checking or changing oil and filters per the manual. It does not restart a stopped compressor or fix a fault, so check the oil level and condition first.
On this page (10 sections)
- How does a service reset on Atlas Copco compressor work?
- What should you check before you reset the service reminder?
- How do you reset the reminder on common Atlas Copco controllers?
- How is a service reset different from restarting a stopped compressor?
- What oil should you use when service is due?
- How often should you reset the service reminder?
- What mistakes should you avoid during a service reset?
- When should you call a service provider instead?
- Which products help after a service reset?
- How should you finish a service reset on Atlas Copco compressor?
A service reset on Atlas Copco compressor means clearing the controller reminder only after you finish the due service, such as checking or changing oil and filters per the manual. It does not restart a stopped compressor or fix a fault, so check the oil level and condition first.
Readers often confuse two different jobs. One job clears a maintenance timer after work is done.
The other job gets a stopped machine ready to run again. This guide keeps those jobs separate.
Atlas Copco models vary a lot in controls. Some use a simple controller with a service timer.
Others use a more advanced controller with menus, alarms, and fault history. Your model manual is the final source for the exact keys and menu path.
How does a service reset on Atlas Copco compressor work?
A service reset works by starting a fresh service interval in the controller after maintenance is complete. The controller then counts run hours from that point toward the next reminder.
That means the reset comes last, not first. You check the oil, service the filters if due, look for leaks, and record the work.
Only then do you clear the reminder.
If you clear it before the work, you lose the signal that service is due. You also risk running a machine on low or dirty oil while the controller shows no warning.
What should you check before you reset the service reminder?
Check oil level, oil condition, filters, leaks, and the manual service list before you touch the controller. A reset never replaces that inspection.
Start with the compressor stopped and isolated as the manual directs. Let hot parts cool and release stored air pressure before you open caps or covers.
Wear eye protection when you work around oil or pressurized parts.
Look at the oil through the sight glass or dipstick if your model has one. The oil should sit in the marked range.
Dark, milky, foamy, or burnt smelling oil calls for a change, not a top up.
Milky oil can point to water in the crankcase. That water can come from short run cycles, cool intake air, or a failed separator or drain routine.
Fix the cause, then change the oil.
How do you reset the reminder on common Atlas Copco controllers?
The exact menu depends on model and controller type, so follow your manual for the key sequence and menu name. Older units may use a basic service timer.
Newer units may hide the reset under a service or maintenance menu.
As a general pattern, you will stop the machine, enter the controller menu, find the service or maintenance section, select reset or confirm service, and enter a code if the model asks for one. Do not guess a code.
Some controllers need a specific access level for service changes. If you cannot reach the reset item, stop and check the manual for the access steps.
A service provider may need to set that level.
After the reset, confirm on screen that the next service point moved forward. Note the date, run hours, and work done in your log.
For a model walkthrough, see How To Reset Atlas Copco Air Compressor? and compare it with your manual before you start.
How is a service reset different from restarting a stopped compressor?
A service reset clears a maintenance reminder after service, while a restart follows the manual to get a stopped machine running again. They solve different problems.
If the compressor stopped on an alarm, find the cause first. A reset will not remove a fault, restore oil pressure, or free a stuck part.
Repeated restarts can damage the motor or the pump.
Check the alarm or fault code on the controller. Look for low oil, high temperature, overload, or a tripped protection device.
Correct that issue, then follow the manual restart steps.
If the machine stopped during freezing weather, it may need thawing and a moisture check first. Our guide on How To Unfreeze An Air Compressor? covers that separate job.
What oil should you use when service is due?
Use the oil type and grade your manual specifies for your model. For many oil lubricated reciprocating units, that means a non detergent compressor oil in the listed grade.
The Milton 1002 is a 1 gallon ISO-100 SAE 30W non detergent oil for reciprocating air compressors. It suits fleet and plant maintenance use and shop or garage machines that see frequent use.

A 1 gallon ISO-100 SAE 30W compressor oil for reciprocating units that call for a non-detergent grade.
See it on AmazonMilton says the oil helps guard against oxidation and corrosion, and its low carbon forming tendency helps limit sludge and carbon deposits. It also separates from water quickly, which supports stable lubrication when moisture enters the system.
How do you choose between compressor oil and other lubricants?
Choose by what the manual calls for inside the pump, not by what you use on other tools. Pump oil needs to resist heat, oxidation, and carbon build up.
General lubricants often do not meet that job.
Super Lube Silicone Oil is a 4 oz bottle of 5000 cSt silicone oil for rubber, plastic, and metal surfaces. It works across a wide temperature range and is NSF H1 registered for incidental food contact.

A small 4 oz silicone oil bottle for rubber, plastic, and metal parts, not a substitute for pump oil.
See it on AmazonUse that kind of silicone oil for small parts, seals, and tools where the maker allows it. Do not pour it into an oil lubricated compressor crankcase unless your manual lists a silicone based pump oil.
Petrol-Gel is a food grade equipment lubricant in a pack of 2 tubes. For pneumatic tools that need food-safe lubrication, compare food grade air tool oils.
It suits machinery parts in contact with food and other general lubrication jobs around a shop.

A pack of 2 food grade lubricant tubes for equipment parts that touch food, not for a compressor pump.
See it on AmazonKeep pump oil, silicone oil, and food grade gel in separate, labeled containers. Mislabeling is a common way expensive oil changes go wrong.
How often should you reset the service reminder?
Reset it only when the service interval comes due and the work is done. The interval your manual lists takes priority over any general guide.
Many shop compressors need oil and filter checks far more often than full oil changes. Short cycles, dust, heat, and moisture can all shorten the practical interval.
Log run hours, dates, oil changes, filter changes, and any water found in the oil or tank. That log helps you spot a pattern before a reminder turns into a fault.
A broader care schedule is in What Maintenance Does an Air Compressor Need?. Pair that schedule with your model manual for the reset timing.
What should you record after a reset?
Record date, run hours, work done, oil type, and the new reminder point. That record protects you if a fault appears soon after service.
Note the oil brand and grade you used, plus the amount added or changed. If you replaced a filter, note the part number.
Keep the log with the machine, not in a phone only.
If the same alarm returns within a short time, the reset did not solve the cause. A pattern of high temperature, oil loss, or water in the oil needs diagnosis, not another reset.
What mistakes should you avoid during a service reset?
Avoid clearing the reminder before service, guessing menu codes, and restarting a faulted machine. Those three errors cause most of the trouble we see in owner reports.
Do not top up oil with a random grade to make the reminder go away. Wrong oil can foam, carbon up, or thin out at heat.
Check the manual grade first.
Do not run the compressor with the filler cap off to check something. Oil can spray out as pressure builds.
Stop the machine, let pressure drop, and check in the safe way the manual describes.
Do not reset the timer while a fault is active. Clear the fault cause first, complete the service, then reset.
If the controller locks you out, contact Atlas Copco support or a qualified service provider.
When should you call a service provider instead?
Call a provider when the reset menu is locked, the fault returns, or oil loss is rapid. Those signs point past a simple reminder clear.
Rapid oil loss can mean a failing ring, seal, or separator. Repeated high temperature can mean poor airflow, a dirty cooler, or a failing fan.
Both need hands on checks beyond a controller menu.
For a new machine, early service questions also tie into break in care. See How To Break In A New Air Compressor? before you clear any timer on a new unit.
You can also check Do I Need To Break In My Air Compressor? to see if your model needs a break in step at all. Some modern units do not.
Which products help after a service reset?
After a reset, keep the right pump oil on hand and use small specialty lubricants only where they fit. The Milton 1002 fits pump oil needs for reciprocating units that call for ISO-100 SAE 30W.
The Super Lube silicone oil fits small rubber, plastic, and metal parts across a wide temperature range. The Petrol-Gel pack fits food contact equipment and general shop lubrication.
For background on the brand and model range, see Where Are Atlas Copco Air Compressors Made?. That context helps when you order parts or oil for a specific unit.
How should you finish a service reset on Atlas Copco compressor?
Finish by confirming the new service point on screen, checking the oil level once more, and running the machine only as the manual directs. Watch the first run for leaks, unusual noise, or alarms.
Run it for a short period, then stop and recheck the oil level. New oil settles and the level can change after the first run.
Top up only with the specified grade.
Keep the service log current. Write down the reset date, run hours, and the next due point.
That simple record prevents the next reminder from turning into overdue service.
Frequently asked questions
What does a service reset on Atlas Copco compressor do?
It clears the service timer or reminder in the controller so the machine starts a new interval. It does not change oil, clean filters, or clear a mechanical fault.
Complete the service listed in the manual before you reset it.
Can I reset the reminder without changing the oil?
No, you should not clear the reminder before completing the due work. If the oil level is low or the oil is dark, top up or change it as the manual directs.
Resetting early can hide overdue maintenance.
Is a service reset the same as restarting a stopped compressor?
No. A restart follows the manual for a stopped machine and checks the cause of the stop.
A service reset only clears a maintenance reminder after service.
Do not use a reset to try to force a stopped compressor to run.
What should I check before I clear the reminder?
Check the oil level, oil condition, filters, air leaks, and the manual service list for your model. Confirm the correct oil type for your compressor.
Then follow the controller menu for your exact model.
About this guide: Our look at resetting a service reminder on an Atlas Copco compressor draws on maker specs, materials and what owners report. See how we research.